Commissioning has two characteristics. A new machine, a new mold and a new material arrive at the same time, so problems stack up; and plenty of issues that look like process problems actually sit in the mechanical datum or an electrical signal. This article walks through eight common problems in two stages — start-up and trial shots — each with a path from root cause to shop-floor action.

1. Classify the Problem Before You Touch Parameters

1.1 Mechanical datum

Leveling, platen parallelism, nozzle alignment, tie bars and guideways. The signature is a stable deviation: it does not disappear after a mold change, a material change or a parameter change, and the defect appears in the same place on every part.

1.2 Hydraulic and electrical

Pressure that will not build, sticking valves, lost limit or signal inputs, heater bands and thermocouples. The signature is intermittent and motion-related: an alarm only at a particular step, or good-bad-good without any parameter change.

1.3 Process

Temperature, speed, position, hold pressure, cooling. The signature is repeatable and parameter-dependent: change one setting and the defect follows. Misclassify the category and every adjustment makes it worse.

2. Four Issues at Start-Up

2.1 No clamp, or clamping interrupted

Usual causes: safety gate limit not made, low-pressure protection threshold too tight, ejectors not returned, mold height set wrong, clamping valve signal missing. Work in order: read the alarm code, check limits and signals, confirm ejector return, temporarily widen the protection threshold to test clamping, and only then suspect mold height and the toggle.

2.2 Clamping force will not build

Usual causes: mold height over-adjusted so the force loads the toggle, hydraulic pressure low or relief valve set too low, platen parallelism out of tolerance, tie bars poorly lubricated and binding. Re-measure parallelism first, then check the pressure gauge against the setpoint, and verify the force reading after adjusting mold height rather than trusting the scale.

2.3 Injection unit creeps, judders or growls

Usual causes: guideway lubrication missing or contaminated, unit speed and back pressure set wrong, servo valve zero drift, mechanical binding, side load from poor nozzle alignment. Clean and lubricate the guideways, run slow no-load strokes to purge, then measure nozzle alignment.

2.4 Nozzle leaking, unstable cushion

Usual causes: nozzle not concentric with the sprue bush, nozzle temperature too high or orifice too large, back pressure and suck-back set wrong, check ring worn. Re-check alignment hot, bring nozzle temperature down, adjust suck-back, inspect the check ring.

3. Four Issues at Trial Shots

3.1 Short shot and flash at the same time

This combination is rarely "not enough pressure". It usually means clamping force is insufficient while injection pressure keeps climbing. Check clamping force against projected area first, then injection capacity (shot size and rate), and only then touch hold pressure.

3.2 Weight and dimension drift

Four usual sources: unstable cushion, worn check ring, temperature fluctuation, unstable cooling water temperature. Work through them in that order — cushion curve first, then mold and water temperature, then metering position repeatability.

3.3 Ejection problems (white marks, cracking, parts stuck)

Mostly ejection force and speed too high, insufficient draft, mold temperature too low, or the ejector plate not returning fully. Reduce ejection speed and step the stroke, check mold temperature, then confirm the mold's ejection structure.

3.4 Low-pressure protection false alarms

A threshold set too tight, a poorly taught mold-contact position, ejector or slider positions that moved, or closing speed too high — any of them will trigger it. Re-teach with the test-block method: a 0.5–1 mm block must alarm, removing it must close normally.

4. Where Konger Design and Service Help

  • Stable datum: the K-TEC series (K-TEC120, K-TEC170, K-TEC1200 and others) uses a split three-platen structure with reinforced platens and a short force path, so datum-drift faults are rarer over years of running.

  • Pressure and temperature under control: servo-driven hydraulics supply oil on demand with a closed pressure loop, and zoned PID barrel control removes the "parameters won't move" illusion.

  • Dedicated platforms: PET preform, artificial flower, TPR soft compound and flame-retardant nylon configurations match screw and nozzle to the material; CMS two-color and sandwich machines cover multi-color work — less forcing a general-purpose machine onto a difficult process.

  • Reusable parameters: process and mold parameters can be saved and recalled, so a mold change does not restart from zero.

  • Service side: Konger covers alignment, trial shots and troubleshooting during installation handover, and can support alarm and parameter reading remotely.

5. Commissioning Acceptance Checklist

  1. Frame leveling and platen parallelism, recorded.

  2. Nozzle alignment readings, cold and hot.

  3. Clamping force calibration with four-corner deviation.

  4. Low-pressure protection verified with a test block.

  5. Hydraulic pressure, oil temperature, cooling water flow.

  6. Measured deviation at each temperature zone.

  7. Ejection and ejector-return signals confirmed.

  8. Process parameters archived with the mold number.

Conclusion

Most commissioning problems are not "parameters not tuned yet" — they are datum, signal or matching issues. Classify first, then follow the path; it is far faster than re-testing settings. Konger's emphasis on structural rigidity, closed-loop pressure and dedicated configurations exists to make these faults rarer and easier to locate when they do appear.