TAG
Nozzle Alignment on Horizontal Injection Molding Machines | Konger
An off-centre nozzle leaks at the sprue bush, destabilises the cushion and wears the bush on one side. A step-by-step method: locating-ring datum, dial-indicator and imprint checks, lateral, height and pitch adjustment, re-check after tightening, and hot-state verification.